# EEGFrontier V1
|
|
|
|
EEGFrontier V1 is a compact EEG acquisition board built around the **ADS1299-4PAGR** and a **Seeed XIAO RP2040**.
|
|
|
|
This repository contains:
|
|
- Hardware design files (KiCad)
|
|
- Firmware (PlatformIO / Arduino)
|
|
- Project assets and documentation images
|
|
|
|
## Important Notice
|
|
|
|
Please check the `bom/` folder for the Bill of Materials and pricing information. A dedicated folder was created specifically to document BOM details and cost references.
|
|
|
|
## Short Project Description
|
|
|
|
**EEGFrontier V1** is an open-source EEG acquisition board designed to capture real brain signals and stream them in real time to a computer for analysis and visualization.
|
|
It focuses on learning, experimentation, and understanding attention and focus using raw EEG data.
|
|
|
|
---
|
|
|
|
## How to Use the Project
|
|
|
|
The board connects to EEG electrodes and streams data over USB to a computer.
|
|
Users flash the firmware to the XIAO RP2040, connect electrodes to the header, and read real-time EEG data using serial tools or custom software written in any language.
|
|
|
|
## Why I Made This Project
|
|
|
|
I made EEGFrontier to learn how real EEG hardware works beyond black-box consumer devices.
|
|
The goal is to make neurotechnology more accessible to students by providing a platform where raw signals, hardware design, and firmware are fully open and modifiable.
|
|
|
|
---
|
|
|
|
## Project Concept
|
|
|
|
The board is designed to connect dry electrodes and stream real-time data from the EEG channels.
|
|
|
|

|
|
|
|
## Hardware Overview
|
|
|
|
### 3D View (Front)
|
|
|
|

|
|
|
|
### 3D View (Back)
|
|
|
|

|
|
|
|
### PCB Layout
|
|
|
|

|
|
|
|
### Schematic
|
|
|
|

|
|
|
|
## Quick Start
|
|
|
|
1. Flash the firmware to the Seeed XIAO RP2040 using PlatformIO
|
|
2. Connect the EEGFrontier board via USB
|
|
3. Attach EEG electrodes (channels, REF, BIAS)
|
|
4. Open Pendulum or a serial monitor
|
|
5. Start streaming with the `START` command
|
|
|
|
## Hardware Highlights
|
|
|
|
- ADS1299-based 4-channel EEG analog front-end
|
|
- Seeed XIAO RP2040 as main controller
|
|
- Header for EEG channels plus reference and bias
|
|
- Start button input (`BTN_START`)
|
|
- Status LEDs (power and stream/activity)
|
|
- Compact PCB with front/back annotated design
|
|
|
|
## Firmware Overview
|
|
|
|
The firmware (in `firmware/`) provides:
|
|
- ADS1299 initialization and register configuration
|
|
- DRDY interrupt-based sampling
|
|
- Binary streaming protocol (COBS + CRC16)
|
|
- CSV debug mode
|
|
- Serial commands for diagnostics and control
|
|
- Recovery logic for acquisition timeout
|
|
- Self-test and lead-off diagnostics
|
|
|
|
## Firmware Build (PlatformIO)
|
|
|
|
```bash
|
|
cd firmware
|
|
pio run -e xiao_rp2040
|
|
```
|
|
|
|
Monitor (default baud rate is `921600`):
|
|
|
|
```bash
|
|
cd firmware
|
|
pio device monitor -b 921600
|
|
```
|
|
|
|
## Serial Commands (Firmware)
|
|
|
|
- `HELP`
|
|
- `INFO`
|
|
- `STATS`
|
|
- `REGS`
|
|
- `START`
|
|
- `STOP`
|
|
- `MODE BIN`
|
|
- `MODE CSV`
|
|
- `REINIT`
|
|
- `TEST ON`
|
|
- `TEST OFF`
|
|
- `SELFTEST`
|
|
- `LOFF ON`
|
|
- `LOFF OFF`
|
|
- `LOFF STATUS`
|
|
- `PING`
|
|
|
|
## Technical Specifications
|
|
|
|
- Channels: 4 EEG channels + REF + BIAS
|
|
- ADC: 24-bit (ADS1299)
|
|
- Sampling rate: configurable (up to ADS1299 limits)
|
|
- Interface: USB (CDC)
|
|
- Power: USB 5V
|
|
|
|
## Repository Structure
|
|
|
|
- `firmware/` - PlatformIO firmware for XIAO RP2040 + ADS1299
|
|
- `assets/` - Images used in this README
|
|
- `EEGFrontier.kicad_sch` / `EEGFrontier.kicad_pcb` - KiCad project files
|
|
- `Pendulum` - Host software
|
|
|
|
## Pendulum
|
|
|
|
**Pendulum** is the host software suite for EEGFrontier: it reads EEG data over USB, offers a local web dashboard (Reflex), and includes a desktop monitor for real-time focus visualization.
|
|
|
|
For full setup and usage instructions, see `Pendulum/README.md`.
|
|
|
|

|
|
|
|

|
|
|
|

|
|
|
|

|
|
|
|
## If you are considering building this
|
|
|
|
I strongly recommend **not** attempting to fully hand-solder this PCB.
|
|
|
|
The board uses fine-pitch components and sensitive analog circuitry, which makes manual soldering difficult and error-prone. Instead, consider ordering the PCB **fully assembled** from a service such as **JLCPCB**.
|
|
|
|
If needed, you can then hand-solder only a few missing components — or none at all if everything is available for assembly.
|
|
|
|
## Safety & Protection
|
|
|
|
⚠️ **Important Safety Notice**
|
|
|
|
This device interfaces electrically with the human body and must be used with caution.
|
|
|
|
- This project **does not include medical-grade isolation** and **must never be connected to mains-powered equipment** without proper USB isolation.
|
|
- Always operate the device using a **battery-powered computer** or a **USB isolator** specifically designed for biomedical signals.
|
|
- Never use the device if any part of the circuit is damaged, exposed, or improperly assembled.
|
|
- Ensure electrodes and cables are clean, dry, and in good condition before use.
|
|
- Do **not** use this device on individuals with implanted electronic devices (e.g. pacemakers).
|
|
- This project is intended **strictly for research, education, and experimentation**.
|
|
|
|
The author assumes **no responsibility for misuse**, improper assembly, or unsafe operating conditions.
|
|
|
|
By using or building this device, you acknowledge that you understand the risks involved in working with bioelectrical signals and accept full responsibility for its use.
|
|
|
|
## Medical Disclaimer
|
|
|
|
This project is **not a medical device** and is **not intended for diagnosis, treatment, or clinical use**.
|
|
|
|
Any data produced by this device should be considered experimental and for educational or research purposes only.
|
|
|
|
## Known Limitations
|
|
|
|
- No medical-grade isolation
|
|
- No onboard battery
|
|
- Susceptible to motion artifacts with dry electrodes
|
|
- Requires external software for filtering and analysis(e.g. Pendulum)
|
|
|
|