- Fuse 2920: terminal length was entered as terminal spacing (Resulted
in too little pad to pad spacing)
- Resitor 1218: body width max was 1mm too large
- 2816: Increased tolerance range for terminal length to fit more
devices.
- Tantal 3528: wrong tolerance range for terminal length
- Tantal 3216 and 6032-28 had wrong tolerance ranges but their effect is
hidden by rounding (meaning no change in the footprint)
- New industry standards have updated not only the fillet sizes but also
the way how tolerances are respected.
- For devices that directly give the lead to lead spacing no complicated
calculations are necessary. (was wrong previously)