Add ESD Protection to Endstops #2
LOADING
daniel
commented 2024-07-28 23:30:24 +00:00
!thumbnail[](Archimajor.PcbDoc){ diff="AllSpice-Demos/Altium-Demo:c285374952fcea88c33ee99a6badbfa58c18cc50...7eaa84ee12e13afc3adee15ebf0e4f30f55007c4" pr="2" layers="82,81,74,72,71,69,68,66,65,64,63,62,60,59,58,57,33,35,37,1,41,40,2,39,32,38,34" diff-visibility="full" variant="default" view-coords="62.1,11.7,82.9,34.8" aspect-ratio="1.347" } @AllSpiceAlice , can you have someone on your team review the new 5V power trace thickness?
AllSpiceAlice
commented 2024-07-28 23:31:52 +00:00
Thank you @daniel, this looks great. All the changes were so quick. Thank you for the expedited layout changes! 🚀
Thank you @daniel, this looks great. All the changes were so quick. Thank you for the expedited layout changes! 🚀
MikaChanical
commented 2024-07-28 23:42:06 +00:00
!thumbnail[](Archimajor.PcbDoc){ diff="AllSpice-Demos/Altium-Demo:c285374952fcea88c33ee99a6badbfa58c18cc50...7eaa84ee12e13afc3adee15ebf0e4f30f55007c4" pr="2" layers="82,81,74,72,71,69,68,66,65,64,63,62,60,59,58,57,33,35,37,1,41,40,2,39,32,38,34" diff-visibility="full" variant="default" view-coords="53.0,0.4,64.8,15.4" aspect-ratio="1.347" } @AllSpiceAlice, new mounting holes are perfect. 🥇
|
@ -1,8 +1,8 @@
|
||||||
Description,Designator,Footprint,Quantity,MANUFACTURER,MANUFACTURER #
|
Description,Designator,Footprint,Quantity,MANUFACTURER,MANUFACTURER #
|
||||||
|
|
||||||
"CAP CER 0603 100nF 50V 10% X7R","C1, C15, C18, C23A, C23B, C23C, C23D, C23E, C36, C47A, C47B, C47C, C47D, C47E, C47F, C47G, C47H, C95, C121A, C121B, C121C, C121D, C121E, C121F, C121G, C121H, C122A, C122B, C122C, C122D, C122E, C122F, C122G, C122H, C199, C202, C203","C0603","37","Kemet","C0603C104K5RACTU"
|
"CAP CER 0603 100nF 50V 10% X7R","C1, C15, C18, C23A, C23B, C23C, C23D, C23E, C36, C47A, C47B, C47C, C47D, C47E, C47F, C47G, C47H, C95, C121A, C121B, C121C, C121D, C121E, C121F, C121G, C121H, C122A, C122B, C122C, C122D, C122E, C122F, C122G, C122H, C199, C202, C203","C0603","37","Kemet","C0603C104K5RACTU"
|
||||||
"CAP CER 0.1UF 6.3V 10% X5R 0201","C2, C60A, C60B, C60C, C60D, C62A, C62B, C62C, C62D, C67, C78, C91, C100, C105, C106, C149A, C149B, C149C, C149D, C149E, C149F, C149G, C149H, C204, C205, C206, C207, C208, C215, C217","C0201 Large Pads","30","Samsung","CL03A104KQ3NNNC"
|
"CAP CER 0.1UF 6.3V 10% X5R 0201","C2, C60A, C60B, C60C, C60D, C60E, C62A, C62B, C62C, C62D, C62E, C67, C78, C91, C100, C105, C106, C149A, C149B, C149C, C149D, C149E, C149F, C149G, C149H, C204, C205, C206, C207, C208, C215, C217","C0201 Large Pads","32","Samsung","CL03A104KQ3NNNC"
|
||||||
"CAP CER 0402 TBD, CAP CER 0402 22pF 50V 5% C0G","C3, C151","C0402","2","TBD, AVX","TBD, 04025A220JAT2A"
|
"CAP CER 0402 TBD","C3","C0402","1","TBD","TBD"
|
||||||
"CAP CER 47UF 10V X5R 1210","C4, C5","C1210","2","Murata","GRM32ER61A476KE20L"
|
"CAP CER 47UF 10V X5R 1210","C4, C5","C1210","2","Murata","GRM32ER61A476KE20L"
|
||||||
"CAP CER 4.7UF 50V X7R 1210","C6, C7, C440","C1210","3","Murata","GRM32ER71H475KA88L"
|
"CAP CER 4.7UF 50V X7R 1210","C6, C7, C440","C1210","3","Murata","GRM32ER71H475KA88L"
|
||||||
"Capacitor Non Polarized","C8, C9, C10, C11, C27, C50, C153, C154, C209, C211","C0603","10","","DNI-C0603TBD"
|
"Capacitor Non Polarized","C8, C9, C10, C11, C27, C50, C153, C154, C209, C211","C0603","10","","DNI-C0603TBD"
|
||||||
|
|
|
LOADING
brendan marked this conversation as resolved
daniel
commented 2024-07-28 23:20:05 +00:00
@RevaReviewa, the extra endstop channel has been removed. Thank you!
!thumbnail[](EndStops.SchDoc){ diff="AllSpice-Demos/Altium-Demo:c285374952fcea88c33ee99a6badbfa58c18cc50...7eaa84ee12e13afc3adee15ebf0e4f30f55007c4" pr="2" diff-visibility="full" variant="default" view-coords="4.8,40.4,49.6,60.8" aspect-ratio="1.286" }
@RevaReviewa, the extra endstop channel has been removed. Thank you!
gautam
commented 2024-09-05 15:39:46 +00:00
!thumbnail[](EndStops.SchDoc){ diff="AllSpice-Demos/Altium-Demo:c285374952fcea88c33ee99a6badbfa58c18cc50...7eaa84ee12e13afc3adee15ebf0e4f30f55007c4" pr="2" diff-visibility="full" variant="default" view-coords="51.6,15.4,93.9,37.3" aspect-ratio="1.286" } @daniel What's up with this?
AllSpiceAlice
commented 2024-09-05 21:19:11 +00:00
We wanted to add ESD protection. The users kept frying the boards when connecting cables.
We wanted to add ESD protection. The users kept frying the boards when connecting cables.
LOADING
brendan marked this conversation as resolved
PavelInPurchasing
commented 2024-07-28 23:23:42 +00:00
!thumbnail[](Fans.SchDoc){ diff="AllSpice-Demos/Altium-Demo:c285374952fcea88c33ee99a6badbfa58c18cc50...7eaa84ee12e13afc3adee15ebf0e4f30f55007c4" pr="2" diff-visibility="full" variant="default" view-coords="21.3,8.6,37.4,29.5" aspect-ratio="1.286" } @daniel, can you replace the LED with something from the approved parts list? We're about to remove this LED because it is end-of-life EOL.
daniel
commented 2024-07-28 23:25:04 +00:00
@PavelInPurchasing, I've switched to a standard APL LED. Thank you! 🙏
@PavelInPurchasing, I've switched to a standard APL LED. Thank you! 🙏
AllSpiceAlice
commented 2024-09-11 17:30:34 +00:00
!thumbnail[](Fans.SchDoc){ diff="AllSpice-Demos/Altium-Demo:c285374952fcea88c33ee99a6badbfa58c18cc50...7eaa84ee12e13afc3adee15ebf0e4f30f55007c4" pr="2" diff-visibility="full" variant="default" view-coords="63.0,27.8,77.1,37.7" aspect-ratio="1.286" } @MikaChanical , is this correct
Loading…
Reference in New Issue
It's the same connector as one of the fan drivers, so technicians and end-users were accidentally pluging in debug equipment into the fan drivers and vice-versa. This was to make it accident-proof.
That makes sense, thank you.