Design Differences 16.6-p001 (v16-6-112A) 9/10/2012
|
|
Cadence Design Systems, Inc.
|
|
(C) Copyright 1994, Cadence Design Systems, Inc.
|
|
|
|
Load design differences view at 17:28:14 Tuesday, May 12, 2015
|
|
--- Ignored Instance Property List ---
|
|
SCH_SIZE
|
|
HAS_FIXED_SIZE
|
|
DES
|
|
PRIM_FILE
|
|
CDS_LIB
|
|
DRAWING
|
|
PATH
|
|
XY
|
|
|
|
*************************************************
|
|
* Loading logical design view of tubii(sch_1) *
|
|
*************************************************
|
|
|
|
Setting design view directives...
|
|
|
|
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged\pstchip.dat
|
|
|
|
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged\pstxprt.dat
|
|
|
|
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged\pstxnet.dat
|
|
Error #38: WARNING(SPCODD-38): Terminating character '=' not found on line 2827.
|
|
|
|
Error #-1: ERROR(SPCODD-47): Packaging can not complete because the file C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged\pstxnet.dat could not be loaded. There might be syntax errors in this file. Ensure that the syntax is correct before proceeding.
|
|
|
|
ERROR(SPCODD-383): Error at line 2827 in file C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged\pstxnet.dat. Error loading the net list file
|
|
|
|
|
|
*****************************************************
|
|
* End loading logical design view of tubii(sch_1) *
|
|
*****************************************************
|
|
|
|
|
|
*********************************************************************************
|
|
* Design Differences failed to create the logical design view of tubii(sch_1) *
|
|
*********************************************************************************
|
|
|
|
|
|
************************************************************
|
|
* Loading physical design view of tubii(TubiiPCB_V5.brd) *
|
|
************************************************************
|
|
|
|
Setting design view directives...
|
|
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged/funcview.dat
|
|
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged/compview.dat
|
|
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged/netview.dat
|
|
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged/pinview.dat
|
|
packaging the design view...
|
|
|
|
****************************************************************
|
|
* End loading physical design view of tubii(TubiiPCB_V5.brd) *
|
|
****************************************************************
|
|
|
|
|
|
*******************************************
|
|
* Generating the design view difference *
|
|
*******************************************
|
|
|
|
--- Ignored Net List ---
|
|
--- Ignored Inst List ---
|
|
|
|
***********************************************
|
|
* End generating the design view difference *
|
|
***********************************************
|
|
|
|
Found Instance Difference: tubii(sch_1) vs. tubii(TubiiPCB_V5.brd)
|
|
Found Net Difference: tubii(sch_1) vs. tubii(TubiiPCB_V5.brd)
|
|
Found Pin-net Connection Difference: tubii(sch_1) vs. tubii(TubiiPCB_V5.brd)
|
|
|
|
********************************************************************
|
|
* Start extracting terminators from board tubii(TubiiPCB_V5.brd) *
|
|
********************************************************************
|
|
|
|
|
|
********************************
|
|
* End extracting terminators *
|
|
********************************
|
|
|
|
Writing project directives...
|
|
Exit Design Differences
|