Tubii_Tk2/worklib/tubii/packaged/dessync.log

86 lines
3.3 KiB
Plaintext

Design Differences 16.6-p001 (v16-6-112A) 9/10/2012
Cadence Design Systems, Inc.
(C) Copyright 1994, Cadence Design Systems, Inc.
Load design differences view at 17:28:14 Tuesday, May 12, 2015
--- Ignored Instance Property List ---
SCH_SIZE
HAS_FIXED_SIZE
DES
PRIM_FILE
CDS_LIB
DRAWING
PATH
XY
*************************************************
* Loading logical design view of tubii(sch_1) *
*************************************************
Setting design view directives...
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged\pstchip.dat
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged\pstxprt.dat
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged\pstxnet.dat
Error #38: WARNING(SPCODD-38): Terminating character '=' not found on line 2827.
Error #-1: ERROR(SPCODD-47): Packaging can not complete because the file C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged\pstxnet.dat could not be loaded. There might be syntax errors in this file. Ensure that the syntax is correct before proceeding.
ERROR(SPCODD-383): Error at line 2827 in file C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged\pstxnet.dat. Error loading the net list file
*****************************************************
* End loading logical design view of tubii(sch_1) *
*****************************************************
*********************************************************************************
* Design Differences failed to create the logical design view of tubii(sch_1) *
*********************************************************************************
************************************************************
* Loading physical design view of tubii(TubiiPCB_V5.brd) *
************************************************************
Setting design view directives...
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged/funcview.dat
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged/compview.dat
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged/netview.dat
Loading... C:\Users\QGPWindowsVB\Documents\ANUSTART\worklib\tubii\packaged/pinview.dat
packaging the design view...
****************************************************************
* End loading physical design view of tubii(TubiiPCB_V5.brd) *
****************************************************************
*******************************************
* Generating the design view difference *
*******************************************
--- Ignored Net List ---
--- Ignored Inst List ---
***********************************************
* End generating the design view difference *
***********************************************
Found Instance Difference: tubii(sch_1) vs. tubii(TubiiPCB_V5.brd)
Found Net Difference: tubii(sch_1) vs. tubii(TubiiPCB_V5.brd)
Found Pin-net Connection Difference: tubii(sch_1) vs. tubii(TubiiPCB_V5.brd)
********************************************************************
* Start extracting terminators from board tubii(TubiiPCB_V5.brd) *
********************************************************************
********************************
* End extracting terminators *
********************************
Writing project directives...
Exit Design Differences